Part Number Hot Search : 
M62413FP LCX007 MT9171 CZRA4760 2SD2143 AO440 01544 SI2343DS
Product Description
Full Text Search
 

To Download AQK1211 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 www..com
UL
C-UL TUV
Pending Pending Pending
AQ-K SOLID STATE RELAY
AQ-K RELAYS
APPLICATIONS
1. Molding machine (heater control) 2. Temperature controlled bath (heater control) 3. Printing machine (heater control) 4. Machine tool (motor control)
FEATURES
1. Combined with heat sink for slim profile Helps to save space on control panel 2. Dielectric voltage of 2,500V or 4,000V 3. Both screw-on installation or onetouch DIN-rail installation available 4. Includes operation LED (red) 5. Built-in varistor
TYPES
Type Load current 15 A Zero-cross 25 A 75 to 250 V AC Load voltage 75 to 250 V AC Breakdown voltage 2,500 V AC 4,000 V AC 2,500 V AC 4,000 V AC Part No. AQK1211 AQK1231 AQK2211 AQK2231
ORDERING INFORMATION
Ex. AQK
Load current 1: 15 A 2: 25 A
Load voltage 2: 75 to 250 V AC
Type 1: Zero-cross type (2,500 V) 3: Zero-cross type (4,000 V)
Input voltage 1: 4.5 to 30 V DC
Note: Standard packing: Carton 10 pcs., Case: 60 pcs.
SPECIFICATIONS
1. Ratings (at 20C 68F, Input ripple: 1% or less) 1) 10 A type
Type Input voltage Input side Input current, max. Drop-out voltage, min. Max. load current Load voltage Frequency Load side Non-repetitive surge current Max. "OFF-state" leakage current Max. "ON-state" voltage drop Min. load current Items AQK1211 AQK1231 AQK2211 4.5 to 30 V DC 10 mA 1V 15 A 75 to 250 V AC 45 to 65 Hz 150 A 250 A 9 mA (when 200 V applied) 1.6 V 100 mA In one cycle at 60 Hz at 60 Hz at max. carrying current 25 A AQK2231 Remarks
See "REFERENCE DATA 1"
74
www..com
AQ-K
AQK1211 AQK1231 AQK2211 AQK2231 (1/2 cycle of voltage sine wave) + 1 ms (1/2 cycle of voltage sine wave) + 1 ms 2,500 V AC 4,000 V AC 2,500 V AC 4,000 V AC -30C to +80C -22F to +176F 100 M between input, output and case 10 to 55 Hz at double amplitude of 0.75 mm Min. 294 m/s2 -35C to +100C -31F to +212F Zero-cross (Turn-ON and Turn-OFF) Remarks
2. Characteristics (at 20C 68F, Input ripple: 1% or less)
Part No. Operate time, max. Release time, max. Breakdown voltage Ambient temperature Insulation resistance, min., Initial Vibration resistance Shock resistance Storage temperature Operational method
Non-condensing at low temperatures by 500V DC megger For 1 min.
DIMENSIONS
65.7 2.587 Max. 22 Max. .866
+3 -4 1 2
mm inch Schematic
3 Input power source 4 Electrode terminal cover 2 1 Load Load power source
Input signal display LED
26.25 1.033 Max. 102 Max. 4.016 77.6 3.055
Mounting dimensions (Bottom view)
35-mm DIN rail installation, or 2-4.6/M4 dia. Screws
10.8 .425 Max. 100 Max. 3.937 90.0 3.543
REFERENCE DATA
1. Load current vs. ambient temperature characteristics
30 Non-repetitive surge current, A 25 Load current, A 20 15A type 15 10 5 0 -30
2. Non-repetitive surge current vs. carrying time (15 A, 25 A type)
300 250 200 15A type 150 100 50 0
3. Input current vs. input voltage characteristics
15
Input current, mA
25A type
25A type
10
5
0
20 40 60 80 Ambient temperature, C
1
2 3 4 5 7 10 20 304050 70 100 No. of cycles at 60 Hz
0
0
5
10
15 20 Input voltage, V
25
30
For Cautions for Use, see Page 24 to 27.
75


▲Up To Search▲   

 
Price & Availability of AQK1211

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .